Dilution Solutions Nutrient Delivery System (NDS) Micro-Doser Kit, 1 1/2 in Right to Left (Hi-Flo)
City: US, Shoemakersville
- Competitive Price Matching
- Fast & Discreet Shipping (2-3 days)
- Safe & Secure Shopping
- High Quality Trusted Brands
eOne MF Proportional Micro-Doser NDS Kit, 1-1/2 Inch, Right-to-Left
The Dilution Solutions eOne MF Micro-Doser NDS Kit (PE0110MF1.5INX1PR-RL) is the 1-1/2-inch Hi-Flo version of the eOne MF proportional dosing pump system in right-to-left orientation. In the RTL configuration, water enters from the right side of the panel and exits to the left — the mirror image of the LTR version. Select the orientation that aligns with the water flow direction at the installation point.
All pump specifications are identical to the 1-1/2-inch LTR version: up to 180 impulses per minute, 0.26 gph flow rate, and a maximum operating pressure of 1.45 psi. The backlit graphic display allows programming of dosing parameters. The complete kit includes the eOne MF 0110 pump, polyethylene panel, PVC suction and discharge tubing, polyethylene discharge tube, water meter, check valve, pressure relief valve, injection valve, unions, foot filter, and mixing chamber.
Key Features & Benefits
- 1-1/2-Inch Hi-Flo System — Panel sized for 1-1/2-inch Hi-Flo NDS installations.
- Right-to-Left Orientation — Water enters from the right and exits to the left.
- Microprocessor Proportional Dosing — Programmable peristaltic pump for precise and consistent concentrate delivery.
- 180 Impulses per Minute — High-frequency dosing capability for precise and consistent concentrate delivery.
- 0.26 GPH Flow Rate — Precise low-flow dosing independent of the main water flow rate.
- Complete Kit — Includes pump, PE panel, suction/discharge tubing, water meter, check valve, foot filter, mixing chamber, and all connections.
Who Should Use This Kit
The 1-1/2-inch RTL eOne MF kit is for Hi-Flo NDS installations where water flows from right to left through the panel. Confirm the physical water flow direction at the installation location before selecting LTR or RTL.
Hi-Flo Panel Orientation and Installation Planning
When planning a 1-1/2-inch Hi-Flo NDS installation, determine the direction water will flow through the system panel before ordering. In a left-to-right installation, the water supply enters from the left and the treated water exits to the right, continuing to the crop irrigation lines. In a right-to-left installation, the positions are reversed. Choosing the wrong orientation can require 180-degree bends or cross-routing in the plumbing, which creates pressure drop and complicates future maintenance.
Frequently Asked Questions
- What is the difference between RTL and LTR for the 1-1/2-inch kit?
- RTL and LTR are mirror-image panel orientations. In RTL, water enters from the right and exits to the left; in LTR, water enters from the left and exits to the right.
- What is included in the kit?
- The kit includes the eOne MF 0110 pump, polyethylene panel, PVC suction tube, PVC priming discharge tube, PE discharge tube, water meter, check valve, pressure relief valve, injection valve, unions, foot filter, and mixing chamber. That's the complete set of hardware needed for a single inline installation.
- What size system is this for?
- The PE0110MF1.5INX1PR-RL is for 1-1/2-inch Hi-Flo NDS installations. For 3/4-inch Lo-Flo systems, use the DSETA.75RTL version instead.
- Are the pump specs the same as the LTR version?
- Yes, LTR and RTL kits use the same eOne MF pump with identical specifications. Only the panel orientation differs between the two.
- How do I plan the plumbing layout for this orientation?
- Determine the water flow direction at the panel location before ordering, since choosing the wrong orientation can require 180-degree bends or cross-routing that create pressure drop. Plan the supply and discharge line routing around the RTL layout — supply from the right, discharge to the left.